The ROM Operating System or simply ROS is the firmware of the System/23. It consists in a set of fourteen to sixteen ROMs of 8KB each, for a total of 112KB/128KB, although the service manual states 112KB which means they did not countupdate the non-pagedcapacity after adding ROMs 10h ROMand memory11h<ref>SY34-0171-0 IBM 5322 Computer Service Manual, page 74</ref>. Each ROS ROM has a unique diagnostics identification code, which is determined by the outputs of two 74LS138 3:8 decoders. ROMs 02h and 09h are fixed in the memory map, where the rest are paged in the memory range 4000h-7FFFh. ROMs 0Eh and 0Fh are not present but the logic to select them is implemented even if there is no place to place them in the board; still, with an appropriate ROM adapter their space could be enabled to inject code into the system.
 
ROMs paged 0-7 are present in the board while ROMs paged 8-15 are expected to be provided by expansion cards on their corresponding slots. Therefore, the maximum theoretical ROM capacity for the Datamaster consists of 272KB if the 0Eh-0Fh gap and pages 8-15 are used.